»ó¼¼ ¼³¸í
¡Ü Work Application Using
- Particulate contamination and hazard including biological agents (viruses and bacteria) at Biosafety Levels 1, 2, 3, or BSL4 suit laboratories
¡Ü ±¸¼º : Stainless Steel interior cabinet walls, manual adjustable height stand, factory installed UV light and one set of armrest
¡Ü Single Piece Stainless Steel Work Tray : ¼¼Ã´ÀÌ ¿ëÀÌÇÔ
¡Ü Sloped Front (10¢ª), Reduced Noise Level
¡Ü Inflow (À¯ÀÔ·®) ¹× Downflow (ÇÏ°­ ±â·ù)ÀÇ ÃÖÀûÈ­ µÈ Balance Control¸¦ À§ÇÑ µ¶¸³µÈ °¢°¢ÀÇ D/C¸ðÅÍ (Inflow Blower, Downflow Blower) ¹× ¼¾¼­ ÀåÂø
¡Ü µ¶¸³µÈ 2°³ÀÇ DC Motor°¡ Inflow¿Í Downflow¸¦ °¢°¢ ´ã´çÇÏ¿© AirflowÀÇ È¿À²ÀÌ ÁÁ°í ÇÊÅÍÀÇ ¼ö¸íÀ» ȹ±âÀûÀ¸·Î Çâ»ó½ÃÅ°°í (ÇÊÅÍ ±³Ã¼ ÁÖ±â : 5³â) ȹ±âÀûÀ¸·Î ¼ÒÀ½À» ÁÙÀÓ
¡Ü Ventillation System (Exhaust Volume): 582 m3/h
¡Ü Inflow ¹× Downflow¿¡ ºÎÂø µÈ °¢°¢ Sensor´Â ÀÚµ¿À¸·Î Airflow¸¦ ControlÇÔ Å¸»ç¹æ½ÄÀÎ Damper¿¡ ÀÇÇÑ ¼öµ¿ AirflowÁ¶ÀýÀÌ ÇÊ¿ä ¾øÀ½
¡Ü Inflow(Exhaust Motor) Sensor´Â HEPA FilterÀÇ ¼ö¸íÀ» ÀÚµ¿À¸·Î °¨Áö, Filter ¿ë·®¿¡ ¸Â°Ô ¹è±â·®À¸·Î ÀÚµ¿ º¸Á¤ÇÔ
¡Ü Digital Airflow Verification (DAVe) : ÃÖÀûÈ­ µÈ Balance Control¸¦ À§ÇÑ »ç¿ëÀÚ °æ°í System
- HEPA FilterÀÇ È¿À²ÀúÇÏ ¹× ±â±â ¿ÀÀÛµ¿À¸·Î ÀÎÇÑ ¼º´ÉÀúÇϽà ÀÚµ¿ °æ°í ¸Þ¼¼Áö ±â´É
- µ¶¸³µÈ Pressure Sensor´Â Exhaust (Inflow)¿Í Downflow°£ÀÇ ¾Ð·Âº¯È­¸¦ ÀÚµ¿À¸·Î °¨Áö
- Exhaust (Inflow) ¶Ç´Â DownflowÀÇ ¼³Á¤°ª º¯È­½Ã ÀÚµ¿ ¾Ë¸²±â´É
»ó¼¼ ±Ô°Ý
»ó¼¼ ±Ô°Ý Ç¥
Cat. No Model Wide ³»ºÎÀçÁú
C10-55-100 TS1376 4 ft (1200 mm) Stainless Steel
C10-55-150 TS1383 5 ft (1500 mm)
C10-55-200 TS1378 6 ft (1800 mm)
Optional Accessory
Cat. No Model Description
C10-55-911 1911308 Combustible Glas Valve (LPG)
C10-55-914 1911309 Non-combustible Gas Valve
C10-55-917 1911310 Vacuum Valve
C10-55-920 1911311 Water Valve
C10-55-923 1911316 Thimble Duct for 4 ft Cabinet
C10-55-930 1911317 Thimble Duct for 6 ft Cabinet
  • ¡Ü Thimble Duct
    - Allows the biological safety cabinet to be connected to an external exhaust for the removal of volatile toxic chemicals or radionuclides used in the cabinet
    - The thimble duct exhaust connection is the method recommeded by NSF/ANSI 49 for externally exhausting the class ¥±, Type A2 biological safety cabinet
»ó¼¼ ±Ô°Ý Ç¥
Cat. No. C10-55-100 C10-55-150 C10-55-200
Model TS1376 TS1383 TS1378
Size Internal w1200¡¿d630¡¿h780 mm w1500¡¿d630¡¿h780 mm w1800¡¿d630¡¿h780 mm
External w1300¡¿d800¡¿h1568 mm w1600¡¿d800¡¿h1568 mm w1900¡¿d800¡¿h1568 mm
Maximum Load 50 kg (Work Tray)
Exhaust/Inflow Air Vol. 585 §©/h 732 §©/h 878 §©/h
Heat Emission 200 W 310 W 400 W
Filter H14 HEPA EN 1822 99.995% at the most penetrating particle size (mini-pleated)
Certification NSF/ANSI 49, UL
Sound 63 dB 65 dB
Light Power > 120 fc
Electric Power 230V, 50/60 Hz, 200W, 1.2A 230V, 50/60 Hz, 310W, 1.5A 230V, 50/60 Hz, 400W, 1.9A
Protection T15 Amp fuse or Class B 15 circuit breaker is required. The local electrical regulations
Access Ports (¥Õ24 mm) 6 (3 on each side)
Valve Up to 6ea (Installed through side wall access ports)
Receptacles (Rear Wall) Sigle, Right Side Two Singe, Left & Right Side
Warranty 3 Years